Free standing TD support

The self-supporting supports for TD enclosures are available in 2 versions:
• For a TGBT enclosure
• For a TGBT cabinet and a mini TD

Configured with a single or double mast, these supports are validated by a calculation note.

They are supplied with the screws, the waterproof protection and the assembly instructions.

• Installation in 10 minutes by 1 person.
• Simplified handling for the installers.


Available in several versions:


Number of ballasts: 6 to 12

Floor space requirement: 1200mm to 1800mm

Mast height: 1200mm to 1800mm
Choose my product between 10 variants You may also be interested in these products

Download documents

Close

Please login

If you wish to download certain technical documents from FIMO Rooftop, please enter your login and password in the fields below.

Don't have an account? Sign up
Forget your password?

Average delivery time in
10 working days
Filter technical constraints
Number of products found (${store.count})
free-standing support TD + mini TD mast Ø88.9 - QP max 69,1
VN61973000990
Maximum number of equipments : 2
Mast diameter (in mm) : 88.9
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 540x300x750 mm and 1 TD with a template ≤ 350x120x435 mm
Number of ballasts : 6
Floor space (Width x length in mm) : 1800x800
Mast height (mm) : 1800
Max wind zone : Zone 2 : up to 24 m/s
Max field category : IV : Urban areas
Max building height (in metres) : 40
Max peak velocity pressure (daN/m²) : 69.1
Free-standing support TD + mini TD mast Ø88.9 - QP max 98,0
VN61973000991
Maximum number of equipments : 2
Mast diameter (in mm) : 88.9
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 540x300x750 mm and 1 TD with a template ≤ 350x120x435 mm
Number of ballasts : 6
Floor space (Width x length in mm) : 1200x1200
Mast height (mm) : 1800
Max wind zone : Zone 3 : up to 26 m/s
Max field category : IIIb : Urbanized or industrial areas
Max building height (in metres) : 40
Max peak velocity pressure (daN/m²) : 98
free-standing TD mast Ø88.9 - QP max 147.9
VN61973001045
Maximum number of equipments : 1
Mast diameter (in mm) : 88.9
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 540x300x750 mm
Number of ballasts : 6
Floor space (Width x length in mm) : 1600x1200
Mast height (mm) : 1800
Max wind zone : Zone 3 : up to 26 m/s
Max field category : 0 : Sea or coastal areas
Max building height (in metres) : 30
Max peak velocity pressure (daN/m²) : 147.9
Mini TD free-standing support - QP max 147.9
VN61973006819
Maximum number of equipments : 1
Mast diameter (in mm) : 88.9
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 350x120x435 mm
Number of ballasts : 3
Floor space (Width x length in mm) : 1200x800
Mast height (mm) : 1200
Max wind zone : Zone 3 : up to 26 m/s
Max field category : 0 : Sea or coastal areas
Max building height (in metres) : 30
Max peak velocity pressure (daN/m²) : 147.9
Free-standing TD mast Ø114.3 - QP max 83.5
VN61973001044
Maximum number of equipments : 1
Mast diameter (in mm) : 114.3
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 540x300x750 mm
Number of ballasts : 4
Floor space (Width x length in mm) : 1200x800
Mast height (mm) : 1800
Max wind zone : Zone 2 : up to 24 m/s
Max field category : IIIb : Urbanized or industrial areas
Max building height (in metres) : 40
Max peak velocity pressure (daN/m²) : 83.5
free-standing TD mast Ø114 - QP max 147.9
VN61973001046
Maximum number of equipments : 1
Mast diameter (in mm) : 114.3
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 540x300x750 mm
Number of ballasts: 6
Floor space (Width x length in mm) : 1600x1200
Mast height (mm): 1800
Max wind zone : Zone 3 : up to 26 m/s
Max field category : 0 : Sea or coastal areas
Max building height (in metres) : 30
Max peak velocity pressure (daN/m²) : 147.9
Maxi TD free-standing support - QP max 147.9
VN61973006818
Maximum number of equipments : 1
Mast diameter (in mm) : 114.3
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 900x400x1100 mm or 1 RBS 6330 Support with a template ≤ 900x425x650 mm
Number of ballasts : 10
Floor space (Width x length in mm) : 1200x2000
Mast height (mm) : 2000
Max wind zone : Zone 3 : up to 26 m/s
Max field category : 0 : Sea or coastal areas
Max building height (in metres) : 30
Max peak velocity pressure (daN/m²) : 147.9
Maxi TD free-standing support - QP max 83.5
VN61973006817
Maximum number of equipments : 1
Mast diameter (in mm) : 114.3
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 900x400x1100 mm or 1 RBS 6330 Support with a template ≤ 900x425x650 mm
Number of ballasts : 8
Floor space (Width x length in mm) : 1200x1600
Mast height (mm) : 2000
Max wind zone : Zone 2 : up to 24 m/s
Max field category : IIIb : Urbanized or industrial areas
Max building height (in metres) : 40
Max peak velocity pressure (daN/m²) : 83.5
Maxi TD + TD free-standing support - QP max 98.0
VN61973006820
Maximum number of equipments : 2
Mast diameter (in mm) : 114.3
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 900x400x1100 mm and 1 TD with a template ≤ 540x300x750 mm
Number of ballasts : 12
Floor space (Width x length in mm) : 1600x1800
Mast height (mm) : 2000
Max wind zone : Zone 3 : up to 26 m/s
Max field category : IIIb : Urbanized or industrial areas
Max building height (in metres) : 40
Max peak velocity pressure (daN/m²) : 98
free-standing TD mast Ø88.9 - QP max 83,5
VN61973001043
Maximum number of equipments : 1
Mast diameter (in mm) : 88.9
Other technical characteristics :
Equipment suitable for 1 TD with a template ≤ 540x300x750 mm
Number of ballasts : 4
Floor space (Width x length in mm) : 1200x800
Mast height (mm) : 1800
Max wind zone : Zone 2 : up to 24 m/s
Max field category : IIIb : Urbanized or industrial areas
Max building height (in metres) : 40
Max peak velocity pressure (daN/m²) : 83.5
Working with FIMO Rooftop means benefiting from…
INNOVATIVE AND SUSTAINABLE SOLUTIONS
CONTROLLED PRESTATION QUALITY
A REAL EXPERTISE IN INTEGRATION
INVOLVED TEAMS
How can we help you?